 |
October-December 2009 Volume 34 | Issue 4
Page Nos. 191-229
Online since Tuesday, September 29, 2009
Accessed 40,715 times.
PDF access policy Journal allows immediate open access to content in HTML + PDF
EPub access policy Full text in EPub is free except for the current issue. Access to the latest issue is reserved only for the paid subscribers.
|
| |
|
Show all abstracts Show selected abstracts Add to my list |
|
EDITORIAL |
|
|
|
Use of Cesium-131 radioactive seeds in prostate permanent implants |
p. 191 |
TS Kehwar DOI:10.4103/0971-6203.56077 PMID:20098547 |
[HTML Full text] [PDF] [Citations (8) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
INVITED PAPER |
 |
|
|
 |
Commissioning experience and quality assurance of helical tomotherapy machines |
p. 194 |
Amarjit Sen, Matthew K West DOI:10.4103/0971-6203.56078 PMID:20098548A helical tomotherapy machine combines a straight 6 MV linear accelerator mounted on a ring gantry with CT technology for image-guided intensity-modulated radiation therapy (IMRT) treatment. A fan beam created by the collimator and jaws produces a maximum of 40 Χ 5 cm 2 field size at the isocenter. The gantry and hence the fan beam rotates at a constant speed while the couch moves linearly into the gantry bore, thus producing a helical delivery. The beam is modulated by a 64-leaf binary multileaf collimator (MLC), which enables IMRT treatment. The linac can be operated at a lower voltage (3.5 MV) and dose rate to produce megavoltage CT images, which are used for image-guided patient setup. We have installed two such units since 2004 and treated more than 2000 patients. The machine comes "precommissioned" from the manufacturer, and the beam characteristics and IMRT plans on phantom are measured and compared with manufacturer's data after acceptance tests are performed on site. Our experience with commissioning the machines and periodic quality assurance with tolerance limits for optimal performance are described. |
[ABSTRACT] [HTML Full text] [PDF] [Citations (3) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
ORIGINAL ARTICLES |
 |
|
|
 |
Different intensity extension methods and their impact on entrance dose in breast radiotherapy: A study |
p. 200 |
A Sankar, J Velmurugan DOI:10.4103/0971-6203.56079 PMID:20098549In breast radiotherapy, skin flashing of treatment fields is important to account for intrafraction movements and setup errors. This study compares the two different intensity extension methods, namely, Virtual Bolus method and skin flash tool method, to provide skin flashing in intensity modulated treatment fields. The impact of these two different intensity extension methods on skin dose was studied by measuring the entrance dose of the treatment fields using semiconductor diode detectors. We found no significant difference in entrance dose due to different methods used for intensity extension. However, in the skin flash tool method, selection of appropriate parameters is important to get optimum fluence extension. |
[ABSTRACT] [HTML Full text] [PDF] [Citations (9) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
 |
Radiobiological modeling of interplay between accelerated repopulation and altered fractionation schedules in head and neck cancer |
p. 206 |
Loredana G Marcu, Eva Bezak DOI:10.4103/0971-6203.56081 PMID:20098550Head and neck cancer represents a challenge for radiation oncologists due to accelerated repopulation of cancer cells during treatment. This study aims to simulate, using Monte Carlo methods, the response of a virtual head and neck tumor to both conventional and altered fractionation schedules in radiotherapy when accelerated repopulation is considered. Although clinical trials are indispensable for evaluation of novel therapeutic techniques, they are time-consuming processes which involve many complex and variable factors for success. Models can overcome some of the limitations encountered by trials as they are able to simulate in less complex environment tumor cell kinetics and dynamics, interaction processes between cells and ionizing radiation and their outcome. Conventional, hyperfractionated and accelerated treatment schedules have been implemented in a previously developed tumor growth model which also incorporates tumor repopulation during treatment. This study focuses on the influence of three main treatment-related parameters, dose per fraction, inter fraction interval and length of treatment gap and gap timing based on RTOG trial data on head and neck cancer, on tumor control. The model has shown that conventionally fractionated radiotherapy is not able to eradicate the stem population of the tumor. Therefore, new techniques such as hyperfractionated/ accelerated radiotherapy schedules should be employed. Furthermore, the correct selection of schedule-related parameters (dose per fraction, time between fractions, treatment gap scheduling) is crucial in overcoming accelerated repopulation. Modeling of treatment regimens and their input parameters can offer better understanding of the radiobiological interactions and also treatment outcome. |
[ABSTRACT] [HTML Full text] [PDF] [Citations (8) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
 |
Monte Carlo simulation studies on scintillation detectors and image reconstruction of brain-phantom tumors in TOFPET |
p. 212 |
Nagendra Nath Mondal DOI:10.4103/0971-6203.56083 PMID:20098551This study presents Monte Carlo Simulation (MCS) results of detection efficiencies, spatial resolutions and resolving powers of a time-of-flight (TOF) PET detector systems. Cerium activated Lutetium Oxyorthosilicate (Lu 2 SiO 5 : Ce in short LSO), Barium Fluoride (BaF 2 ) and BriLanCe 380 (Cerium doped Lanthanum tri-Bromide, in short LaBr 3 ) scintillation crystals are studied in view of their good time and energy resolutions and shorter decay times. The results of MCS based on GEANT show that spatial resolution, detection efficiency and resolving power of LSO are better than those of BaF 2 and LaBr 3 , although it possesses inferior time and energy resolutions. Instead of the conventional position reconstruction method, newly established image reconstruction (talked about in the previous work) method is applied to produce high-tech images. Validation is a momentous step to ensure that this imaging method fulfills all purposes of motivation discussed by reconstructing images of two tumors in a brain phantom. |
[ABSTRACT] [HTML Full text] [PDF] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations |
p. 217 |
Roshan S Livingstone, Paul M Dinakaran, Rekha S Cherian, Anu Eapen DOI:10.4103/0971-6203.56085 PMID:20098552Computed tomography (CT) of the abdomen contributes a substantial amount of man-made radiation dose to patients and use of this modality is on the increase. This study intends to compare radiation dose and image quality using dose modulation techniques and weight- based protocol exposure parameters for biphasic abdominal CT. Using a six-slice CT scanner, a prospective study of 426 patients who underwent abdominal CT examinations was performed. Constant tube potentials of 90 kV and 120 kV were used for all arterial and portal venous phase respectively. The tube current-time product for weight-based protocol was optimized according to patient's body weight; this was automatically selected in dose modulations. The effective dose using weight-based protocol, angular and z-axis dose modulation was 11.3 mSv, 9.5 mSv and 8.2 mSv respectively for the patient's body weight ranging from 40 to 60 kg. For patients of body weights ranging 60 to 80 kg, the effective doses were 13.2 mSv, 11.2 mSv and 10.6 mSv respectively. The use of dose modulation technique resulted in a reduction of 16 to 28% in radiation dose with acceptable diagnostic accuracy in comparison to the use of weight-based protocol settings. |
[ABSTRACT] [HTML Full text] [PDF] [Citations (9) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
TECHNICAL NOTE |
 |
|
|
 |
Simple technique for fabrication of shielding blocks for total body irradiation at extended treatment distances |
p. 223 |
R Ravichandran, JP Binukumar, CA Davis, AM Zahid, B Rajan DOI:10.4103/0971-6203.56084 PMID:20098553Techniques are being standardized in our department for total body irradiation (TBI) with six MV photons in linear accelerator for preconditioning to bone marrow transplantation (BMT). Individualized shields with low melting point alloy are to be fabricated for shielding critical organs such as lungs, kidneys etc. A method to mount diminished dimension of shields in a tray at 3.75m is designed in the department for a teletreatment distance of four meters with magna field with A simulator image taken with the patient's midplane (MP) at one meter distance is used to mark the dimensions of lung, scaled down by a factor of 3.75/4.0. These lung dimensions are reprinted from the digital simulator image for making the shield. The methodology of the technique using digitized minification in radiography is the first of its kind to be used for shield cutting in magna field radiotherapy. |
[ABSTRACT] [HTML Full text] [PDF] [Citations (4) ] [PubMed] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
BOOK REVIEW |
 |
|
|
|
Topics in accelerator health physics: HPS professional development school proceedings |
p. 226 |
Marc Mackenzie |
[HTML Full text] [PDF] [Sword Plugin for Repository]Beta |
|
|
|
|
|
|
NEWS |
 |
|
|
|
News |
p. 227 |
T Ganesh |
[HTML Full text] [PDF] [Sword Plugin for Repository]Beta |
|
|
|
|
|