Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of AMPI, IOMP and AFOMP      
 Users online: 933  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 46  |  Issue : 3  |  Page : 140-147

Magnetic resonance neurography of the brachial plexus using 3D SHINKEI: Comparative evaluation with conventional magnetic resonance sequences for the visualization of anatomy and detection of nerve injury at 1.5t


1 Department of Radiodiagnosis and Imaging, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Bengaluru, Karnataka, India
2 Philips India Ltd., Bengaluru, Karnataka, India
3 Department of Statistics, Prasanna School of Public Health, Manipal Academy of Higher Education, Gurgaon, Haryana, India
4 Philips India Ltd., Gurgaon, Haryana, India

Correspondence Address:
Dr. Rajagopal Kadavigere
Department of Radiodiagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal 576 104, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_13_21

Rights and Permissions

Background and Purpose: This work aims at optimizing and studying the feasibility of imaging the brachial plexus at 1.5T using 3D nerve-SHeath signal increased with INKed rest-tissue RARE imaging (3D SHINKEI) neurography sequence by comparing with routine sequences. Materials and Methods: The study was performed on a 1.5T Achieva scanner. It was designed in two parts: (a) Optimization of SHINKEI sequence at 1.5T; and (b) Feasibility study of the optimized SHINKEI sequence for generating clinical quality magnetic resonance neurography images at 1.5T. Simulations and volunteer experiments were conducted to optimize the T2 preparation duration for optimum nerve-muscle contrast at 1.5T. Images from the sequence under study and other routine sequences from 24 patients clinically referred for brachial plexus imaging were scored by a panel of radiologists for diagnostic quality. Injury detection efficacy of these sequences were evaluated against the surgical information available from seven patients. Results: T2 preparation duration of 50 ms gives the best contrast to noise between nerve and muscle. The images of 3D SHINKEI and short-term inversion recovery turbo spin-echo sequences are of similar diagnostic quality but significantly better than diffusion weighted imaging with background signal suppression. In comparison with the surgical findings, 3D SHINKEI has the lowest specificity; however, it had the highest sensitivity and predictive efficacy compared to other routine sequences. Conclusion: 3D SHINKEI sequence provides a good nerve–muscle contrast and has high predictive efficacy of nerve injury, indicating that it is a potential screening sequence candidate for brachial plexus scans at 1.5T also.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed440    
    Printed6    
    Emailed0    
    PDF Downloaded71    
    Comments [Add]    

Recommend this journal