Journal of Medical Physics

Year
: 1998  |  Volume : 23  |  Issue : 4  |  Page : 283--286

An Assessment Of Patient Exposure And Radiation Protection Aspects In Diagnostic Radiology


A.S Mollah1, Maniruzzaman Khan2, M.A Zaman3 
1 
2 
3 

Correspondence Address:
A.S Mollah


The radiation doses due to X-ray radiation of 26 diagnostic installations in Dhaka city have been measured using thermoluminescence dosimeter (TLD-100) and portable dose rate meter. General information about every installation has been recorded. Measurements have been carried out for patient«SQ»s entrance skin dose levels for various types of X-ray projections and for dose rates at some specific locations (e.g., control panel, inside and outside of the door). The organ and effective doses have been estimated by using a computer program PREPARES. Doses for six organs for female and four organs for male patients have been estimated using this program. The present measurements will provide a useful baseline for future measurements and will be used to evaluate the collective doses to the population from medical exposures and the radiation risks from the various radiological procedures.


How to cite this article:
Mollah A, Khan M, Zaman M. An Assessment Of Patient Exposure And Radiation Protection Aspects In Diagnostic Radiology.J Med Phys 1998;23:283-286


How to cite this URL:
Mollah A, Khan M, Zaman M. An Assessment Of Patient Exposure And Radiation Protection Aspects In Diagnostic Radiology. J Med Phys [serial online] 1998 [cited 2019 Oct 18 ];23:283-286