Simple electronic portal imager-based pretreatment quality assurance using Acuros XB: A feasibility study


1 Department of Medical Physics, Bharathiar University, Coimbatore, Tamil Nadu, India
2 Department of Radiation Oncology, Fortis Memorial Research Institute, Gurgaon, India
3 Department of Radiotherapy, Government General Hospital, Guntur, Andhra Pradesh, India

Correspondence Address:
Dr. Sureka Chandra Sekaran
Department of Medical Physics, Bharathiar University, Coimbatore - 641 046, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_84_19

Rights and Permissions

Objective: This study demonstrates a novel electronic portal imaging device (EPID)-based forward dosimetry approach for pretreatment quality assurance aided by a treatment planning system (TPS). Materials and Methods: Dynamic multileaf collimator intensity-modulated radiation therapy (IMRT) plans were delivered in EPID and fluence was captured on a beam-by-beam basis (FEPID). An open field having dimensions equal to those of the largest IMRT field was used in the TPS to obtain the transmitted fluence. This represented the patient-specific heterogeneity correction (Fhet). To obtain the resultant heterogeneity-corrected fluence, EPID measured fluence was corrected for the TPS generated heterogeneity (FResultant= FEPID× Fhet). Next, the calculated fluence per beam basis was collected from TPS (FTPS). Finally, FResultantand FTPSwere compared using a 3% percentage dose difference (% DD)-3 mm distance to agreement [DTA] gamma analysis in an isocentric plane (two-dimensional [2D]) and multiple planes (quasi three-dimensional [3D]) orthogonal to the beam axis. Results: The 2D heterogeneity-corrected dose reconstruction revealed a mean γ passing of the pelvis, thorax, and head-and-neck cases of 96.3% ±2.0%, 96.3% ±1.8%, and 96.1% ±2.2%, respectively. Quasi-3D γ passing for the pelvis, thorax, and head-and-neck cases were 97.5% ±1.4%, 96.3% ±2.4%, and 97.5% ±1.0%, respectively. Conclusion: EPID dosimetry produced an inferior result due to no heterogeneity corrections for sites such as the lung and esophagus. Incorporating TPS-based heterogeneity correction improved the EPID dosimetry result for those sites with large heterogeneity.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed543    
    Printed34    
    Emailed0    
    PDF Downloaded162    
    Comments [Add]    

Recommend this journal