Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of Association of Medical Physicists of India      
 Users online: 348  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
TECHNICAL NOTE
Year : 2019  |  Volume : 44  |  Issue : 1  |  Page : 65-67

Determination of optimal clinical target volume to planning target volume margins for conformal radiotherapy planning using image guidance system in rectal cancer in prone position


Department of Radiotherapy, Dr. Bhubaneshwar Borooah Cancer Institute, Guwahati, Assam, India

Correspondence Address:
Dr. Mouchumee Bhattacharyya
Dr. Bhubaneshwar Borooah Cancer Institute, Gopinath Nagar, Guwahati - 781 016, Assam
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_74_18

Rights and Permissions

Context: In advanced radiotherapy techniques such as three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), geometrical uncertainties are very crucial as they may lead to under dosing of tumor and over dosing of the nearby critical structures and hence, it is important to determine planning target volume (PTV) margins which are specific for every center. Aims: The aim of this study is to determine adequate clinical target volume (CTV) to PTV margins specific to our radiotherapy center. Settings and Design: To calculate CTV to PTV margins for rectal cancer patients in prone position using kV cone beam CBCT data sets. Materials and Methods: With the Patient immobilized in prone position using thermoplastic mask, a CT simulation was done and a comprehensive 3DCRT plan was generated. Daily kV CBCT was done to check the patient setup error. Daily setup errors were recorded and evaluated retrospectively. Results: CTV-PTV margin calculated for pelvis in the prone position was calculated using van Herk Formula and were found to be 0.5, 1.8, 0.7 cm in the lateral, longitudinal, and vertical directions, respectively. Conclusions: Image guidance is an effective method to evaluate patient setup errors. Good quality immobilization devices and stringent patient setup policies can help to reduce PTV margins further.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed69    
    Printed1    
    Emailed0    
    PDF Downloaded7    
    Comments [Add]    

Recommend this journal