TECHNICAL NOTE
Year : 2018  |  Volume : 43  |  Issue : 3  |  Page : 200-203

Assessment of diagnostic reference level in radiography of neonatal chest anteroposterior examination: A hospital-based study


1 Department of Radiation Oncology, State Cancer Institute, Gauhati Medical College, Guwahati, Assam, India
2 Department of Pulmonary Medicine, Gauhati Medical College, Guwahati, Assam, India
3 Department of Radiology, Gauhati Medical College, Guwahati, Assam, India

Correspondence Address:
Mr. Jibon Sharma
State Cancer Institute, Gauhati Medical College, Guwahati - 781 032, Assam
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_37_18

Rights and Permissions

Radiological imaging is an important modality of today's overall practicum. Imaging can begin as early as the 1st day of life. Neonates are 3–4 times more sensitive to radiation than adults. The purpose of the work was to assess the diagnostic reference level (DRL), the radiation organ dose, and effective organ dose for both sexes from chest anteroposterior radiograph, which is the most common radiographic examination performed at the Neonatal Intensive Care Unit (NICU). The entrance air kerma was measured using a solid-state PIN type detector, and the value was used as the input factor to PCXMC-2.0 software to calculate the entrance surface air kerma (ESAK), patient-specific organ dose, and effective dose originated from chest anteroposterior examinations of neonates at NICU. The mean value of ESAK is taken as a diagnostic reference level (DRL) for neonates (both male and female). The mean ESAK value of male neonates is (79.6 ± 1.4) μGy and for female is (79.9 ± 1.9) μGy, and the institutional diagnostic reference level (DRL) is 80.35 μGy for male and 81.2 μGy for female (i.e., third quartile value). A statistical dependency (correlation) between neonates body mass index (BMI) and ESAK was defined for both the sexes. Significant positive correlation was found between ESAK per patient with respect to BMI of both male (R = 0.83, P = 0.00001) and female (R = 0.72, P = 0.00055) neonates. The results for neonatal dose in NICU were compatible with the literature. The result presented will serve as baseline data for the selection of technical parameters in neonatal chest anteroposterior X-ray examination.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed156    
    Printed0    
    Emailed0    
    PDF Downloaded51    
    Comments [Add]    

Recommend this journal