Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of Association of Medical Physicists of India      
 Users online: 354  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
TECHNICAL NOTE
Year : 2018  |  Volume : 43  |  Issue : 3  |  Page : 195-199

Monte Carlo simulation on the imaging contrast enhancement in nanoparticle-enhanced radiotherapy


1 Department of Physics, Ryerson University, Toronto, ON, Canada
2 Princess Margaret Cancer Centre, UHN; Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada

Correspondence Address:
Dr. James C. L. Chow
Princess Margaret Cancer Centre, UHN, Toronto, ON; Department of Radiation Oncology, University of Toronto, 700 University Avenue, Toronto, ON M5G 1Z5
Canada
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_141_17

Rights and Permissions

This study focused on the imaging in radiotherapy by finding the relationship between the imaging contrast ratio and appropriate gold, iodine, iron oxide, silver, and platinum nanoparticle concentrations; the relationship between the imaging contrast ratio and different beam energies for the different nanoparticle concentrations; the relationship between the contrast ratio and various beam energies for gold nanoparticles; and the relationship between the contrast ratio and different thicknesses of the incident layer of the phantom including variety of gold nanoparticles (GNPs) concentration. Monte Carlo simulation was used to model the gold, iodine, iron oxide, silver, and platinum nanoparticle concentration which were infused within a heterogeneous phantom (50 cm × 50 cm × 10.5 cm) choosing different concentrations (3, 7, 18, 30, and 40 mg), and beams (100, 120, 130, and 140 kVp) correspondingly that were delivered into the phantom. The results showed obvious connection between the high concentration and having a high imaging contrast ratio, low energy and a high contrast ratio, small thickness, and a high contrast ratio. The superior nanoparticle obtained was GNP, the better concentration was 40 mg, the better beam energy was 100 kVp, and the better thickness was 0.5 cm. It is concluded that our study successfully proved that medical imaging contrast could be improved by increasing the contrast ratio using GNP as the finest choice to accomplish this improvement considering a high concentration, low beam energy, and a small thickness.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed180    
    Printed1    
    Emailed0    
    PDF Downloaded22    
    Comments [Add]    

Recommend this journal