Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of Association of Medical Physicists of India      
 Users online: 417  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
TECHNICAL NOTE
Year : 2018  |  Volume : 43  |  Issue : 2  |  Page : 112-118

Patient-Specific quality assurance protocol for volumetric modulated arc therapy using dose volume histogram


1 GenesisCare Radiation Oncology Centre, Berwick, VIC, Australia
2 North West Cancer Centre, North West Regional Hospital, Burnie, TAS, Australia

Correspondence Address:
Mr. Christopher Low
Genesiscare Radiation Oncology Centre Berwick, 55 Kangan Drive, Berwick VIC 3806
Australia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_138_17

Rights and Permissions

A retrospective study was performed to explore the use of dose volume histogram (DVH) metrics in a patient-specific quality assurance protocol for volumetric modulated arc therapy (VMAT). Fourteen head and neck (HN) and ten brain patients treated with VMAT at the Launceston General Hospital were retrospectively analyzed using the new protocol to identify cases where patient dose errors exceed the established action levels that were not originally detected by either point dose and/or gamma index methods. The Sun Nuclear 3DVH software was used to estimate the dose delivered to the patient volume in terms of DVH dose errors. Thus, three different pretreatment verification methods were used to assess if a plan was considered acceptable. In two particular cases, the dose difference determined with point dose was above the established threshold, although it was found that this was due to the placement of the chamber in the phantom. In all cases, 3DVH confirmed that the dose delivered to target volumes (planning target volume – D50%) and to relevant organs at risk was within prescribed dose tolerances.This study has demonstrated the integration of DVH metrics into a VMAT PSQA protocol to provide clinically meaningful results that complement point dose and gamma index measurements. 3DVH should be regarded as an investigative tool that may be useful in diagnosing the cause of failed plans since it allows dose errors to be related to the patient anatomy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed381    
    Printed11    
    Emailed0    
    PDF Downloaded77    
    Comments [Add]    

Recommend this journal