Journal of Medical Physics
 Home | Search | Ahead of print | Current Issue | Archives | Instructions | Subscription | Login  The official journal of Association of Medical Physicists of India      
 Users online: 553  Home  EMail this page Print this page Decrease font size Default font size Increase font size 
TECHNICAL NOTE
Year : 2017  |  Volume : 42  |  Issue : 4  |  Page : 251-257

Evaluation and performance of arccheck and film using gamma criteria in pre-treatment quality assurance of stereotactic ablative radiotherapy


1 Peter MacCallum Cancer Centre, Melbourne, Victoria; Medical Radiation Discipline, School of Health and Biomedical Science, RMIT University, Bundoora, Victoria, Australia
2 Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
3 Medical Radiation Discipline, School of Health and Biomedical Science, RMIT University, Bundoora, Victoria, Australia

Correspondence Address:
Prabhakar Ramachandran
Peter Maccallum Cancer Centre, Melbourne, Victoria
Australia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jmp.JMP_132_16

Rights and Permissions

Aim: The aim of this study is to assess the use of ArcCHECK (AC) as an alternative method to replace film dosimetry for pre-treatment quality assurance (QA) of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) stereotactic ablative radiotherapy (SABR) treatment plans. Materials and Methods: Twenty-five patients with a varied diagnosis of lung, spine, sacrum, sternum, ribs, scapula, and femur undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients using ionization chamber and film dosimetry. Measurements were also carried out on an AC phantom. The planned and measured doses from the AC device and EBT3 films were compared using four different gamma criteria: 2%/2 mm, 3%/2 mm, 3%/1 mm, and 3%/3 mm. Results: The mean gamma passing rates at 3%/3 mm for all non-spine SABR cases were 98.79 ± 0.96 and 99.27 ± 1.03 with AC and films, respectively. The mean passing rates at 3%/2 mm for AC and films were 98.76 ± 0.42 and 99.43 ± 0.27 respectively for spine VMAT SABR, and 87.15 ± 2.45 and 99.79 ± 0.14 respectively for spine IMRT SABR. In the case of spine tumors, the gamma criterion was tightened due to the proximity of spinal cord to the planning target volume. Our results show that AC provides good results for all VMAT SABR plans. Conclusion: The AC results at 3%/3 mm were in good agreement with film dosimetry for most cases. We observed a significant reduction in QA time on using AC for SABR QA. This study showed that AC results are comparable to film dosimetry for all studied sites except for spine IMRT SABR.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed786    
    Printed25    
    Emailed0    
    PDF Downloaded79    
    Comments [Add]    

Recommend this journal