A phantom study on the behavior of Acuros XB algorithm in flattening filter free photon beams


Department of Radiation Physics, American Oncology Institute, CTSH, Hyderabad, Telangana, India

Correspondence Address:
K R Muralidhar
American Oncology Institute, CTSH, Nallagandla, Serilingampally, Hyderabad - 500 019, Telangana
India
Login to access the Email id

Source of Support: Nil., Conflict of Interest: There are no conflicts of interest.


DOI: 10.4103/0971-6203.165076

Rights and Permissions

To study the behavior of Acuros XB algorithm for flattening filter free (FFF) photon beams in comparison with the anisotropic analytical algorithm (AAA) when applied to homogeneous and heterogeneous phantoms in conventional and RapidArc techniques. Acuros XB (Eclipse version 10.0, Varian Medical Systems, CA, USA) and AAA algorithms were used to calculate dose distributions for both 6X FFF and 10X FFF energies. RapidArc plans were created on Catphan phantom 504 and conventional plans on virtual homogeneous water phantom 30 × 30 × 30 cm3, virtual heterogeneous phantom with various inserts and on solid water phantom with air cavity. Dose at various inserts with different densities were measured in both AAA and Acuros algorithms. The maximum % variation in dose was observed in (−944 HU) air insert and minimum in (85 HU) acrylic insert in both 6X FFF and 10X FFF photons. Less than 1% variation observed between −149 HU and 282 HU for both energies. At −40 HU and 765 HU Acuros behaved quite contrarily with 10X FFF. Maximum % variation in dose was observed in less HU values and minimum variation in higher HU values for both FFF energies. Global maximum dose observed at higher depths for Acuros for both energies compared with AAA. Increase in dose was observed with Acuros algorithm in almost all densities and decrease at few densities ranging from 282 to 643 HU values. Field size, depth, beam energy, and material density influenced the dose difference between two algorithms.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1273    
    Printed28    
    Emailed1    
    PDF Downloaded171    
    Comments [Add]    

Recommend this journal