ORIGINAL ARTICLE
Year : 2015  |  Volume : 40  |  Issue : 3  |  Page : 136-143

Simulation of the 6 MV Elekta Synergy Platform linac photon beam using Geant4 Application for Tomographic Emission


1 Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First; Department of Physics, Regional Hassan II Oncology Center, Oujda 60000, Morocco
2 Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda; Department of Physics, National School of Applied sciences of Al-Hoceima, Morocco
3 Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda, Morocco

Correspondence Address:
Tayalati Yahya
LPMR, University Mohammed First, P. O. Box 717, Oujda 60000
Morocco
Login to access the Email id

Source of Support: This project is funded by the National Center for Scientific and Technical Research CNRST (URAC07), the High Energy Physics Cluster (RUPHE) and the Spanich-Moroccans PCI2012 (A1/035250/11)., Conflict of Interest: There are no conflicts of interest.


DOI: 10.4103/0971-6203.165077

Rights and Permissions

The present work validates the Geant4 Application for Tomographic Emission Monte Carlo software for the simulation of a 6 MV photon beam given by Elekta Synergy Platform medical linear accelerator treatment head. The simulation includes the major components of the linear accelerator (LINAC) with multi-leaf collimator and a homogeneous water phantom. Calculations were performed for the photon beam with several treatment field sizes ranging from 5 cm × 5 cm to 30 cm × 30 cm at 100 cm distance from the source. The simulation was successfully validated by comparison with experimental distributions. Good agreement between simulations and measurements was observed, with dose differences of about 0.02% and 2.5% for depth doses and lateral dose profiles, respectively. This agreement was also emphasized by the Kolmogorov–Smirnov goodness-of-fit test and by the gamma-index comparisons where more than 99% of the points for all simulations fulfill the quality assurance criteria of 2 mm/2%.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3441    
    Printed68    
    Emailed0    
    PDF Downloaded131    
    Comments [Add]    

Recommend this journal