Impact of repeat computerized tomography replans in the radiation therapy of head and neck cancers


1 Department of Radiotherapy, Sri Aurobindo Institute of Medical Sciences, Indore, Madhya Pradesh, India
2 Bundelkhand Medical College, Sagar, Madhya Pradesh, India

Correspondence Address:
Virendra Bhandari
401, Samyak Towers, 16/3, Old Palasia, Indore - 452 001, Madhya Pradesh
India
Login to access the Email id

Source of Support: Equipment support from Roentgen Oncologic Solutions Pvt. Ltd., and Sri Aurobindo Institute of Medical Sciences, Indore (India)., Conflict of Interest: None


DOI: 10.4103/0971-6203.139005

Rights and Permissions

Anatomical changes can occur during course of head-and-neck (H and N) radiotherapy like tumor shrinkage, decreased edema and/or weight loss. This can lead to discrepancies in planned and delivered dose increasing the dose to organs at risk. A study was conducted to determine the volumetric and dosimetric changes with the help of repeat computed tomography (CT) and replanning for selected H and N cancer patients treated with IMRT plans to see for these effects. In 15 patients with primary H and N cancer, a repeat CT scan after 3 rd week of radiotherapy was done when it was clinically indicated and then two plans were generated on repeat CT scan, actual plan (AP) planned on repeat CT scan, and hybrid plan (HP), which was generated by applying the first intensity-modulated radiation therapy (IMRT) plan (including monitoring units) to the images of second CT scan. Both plans (AP and HP) on repeat CT scan were compared for volumetric and dosimetric parameter. The mean variation in volumes between CT and repeat CT were 44.32 cc, 82.2 cc, and 149.83 cc for gross tumor volume (GTV), clinical target volumes (CTV), and planning target volume (PTV), respectively. Mean conformity index and homogeneity index was 0.68 and 1.07, respectively for AP and 0.5 and 1.16, respectively for HP. Mean D 95 and D 99 of PTV was 97.92% (standard deviation, SD 2.32) and 93.4% (SD 3.75), respectively for AP and 92.8% (SD 3.83) and 82.8% (SD 8.0), respectively for HP. Increase in mean doses to right parotid, left parotid, spine, and brainstem were 5.56 Gy (D mean ), 3.28 Gy (D mean ), 1.25 Gy (D max ), and 3.88 Gy (D max ), respectively in HP compared to AP. Repeat CT and replanning reduces the chance of discrepancies in delivered dose due to volume changes and also improves coverage to target volume and further reduces dose to organ at risk.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1720    
    Printed51    
    Emailed6    
    PDF Downloaded106    
    Comments [Add]    

Recommend this journal