Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes


Department of Radiation Oncology, Arizona Center for Cancer Care, Peoria, Arizona, USA

Correspondence Address:
Suresh Rana
14155 N. 83rd Avenue #127, Arizona Center for Cancer Care, Peoria, Arizona 85381
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-6203.106600

Rights and Permissions

In this study, dose prediction accuracy of Acuros XB (AXB) dose calculation algorithm beyond air gap thickness (range 2, 4, and 6 cm) in simple inhomogeneous phantoms was investigated. The evaluation of AXB was performed by comparing the doses calculated by AXB with the doses calculated by Anisotropic Analytical Algorithm (AAA) and the measured data for different field sizes (3 × 3, 5 × 5, and 10 × 10 cm 2 ) of a 6 MV photon beam. The dose computation was performed within Eclipse treatment planning system, and measurements were acquired with a cylindrical ionization chamber. Central axis depth dose comparisons were done in solid-water material region up to 5 cm distance from air/solid-water interface. The results of AXB had better agreement with measurements at all measured points than that of AAA. The discrepancies between AXB and measured data were seen from − 3.81% to + 0.9%, whereas the AAA differences with measurement from − 3.1% to − 10.9%. The combination of the smallest test field size and the largest air gap produced the highest range (1-5 cm distance from air/solid-water interface) in dose difference (AAA: −4.0% to − 10.6% and AXB: −3.8% to + 0.6%). The AAA computational time was about 8 times faster than that of AXB. In conclusion, AXB is more appropriate to use for dose predictions, especially when low-density heterogeneities are involved.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed10447    
    Printed306    
    Emailed4    
    PDF Downloaded480    
    Comments [Add]    
    Cited by others 10    

Recommend this journal