TECHNICAL NOTE
Year : 2008  |  Volume : 33  |  Issue : 1  |  Page : 24-28

Solid water phantom heat conduction: Heating and cooling rates


1 Department of Medical Physics, Illawarra Cancer Care Centre, Wollongong, NSW 2500; Centre for Medical Radiation Physics, University of Wollongong, Gwyneville 2518, NSW, Australia
2 Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong, Hong Kong S.A.R.

Correspondence Address:
Martin J Butson
Department of Medical Physics, P.O. Box 1798, Wollongong 2500, NSW
Australia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0971-6203.39421

Rights and Permissions

Solid water is often the phantom material of choice for dosimetry procedures in radiotherapy high-energy X-ray and electron beam radiation calibration and quality assurance. This note investigates variation in heat conduction that can occur for a common commercially available solid water stack phantom when a temperature differential occurs between the phantom and ambient temperature. These variations in temperature can then affect radiation measurements and thus the accuracy of radiation dosimetry. In this manuscript, we aim to investigate the variations in temperature which can occur in radiation measurement incorporated (RMI) solid water phantoms, their thermal properties and the effects on radiation dosimetry which can occur because of temperature differentials. Results have shown that the rate of temperature change at a phantom center is a complex function but appears relatively proportional to the surface area of the phantom in normal clinical usage. It is also dependent on the thermal conductivity of any material in contact with the phantom; and the nature of the phantom construction, i.e., the number and thickness of slices within the phantom. A thermal time constant of approximately 20 min was measured for a 2-cm solid water phantom slice when located on a steel workbench in comparison to 60 min when located on a wooden workbench (linac couch insert). It is found that for larger solid water stack phantoms, a transient (within 1C) thermal equilibrium exists at the center for up to 2 h, before the temperature begins to change. This is assumed to be due to the insulating properties of multiple slices within the stack, whereby very small air spaces are introduced inhibiting the heat conduction through the phantom material. It is therefore recommended that the solid water/phantom material is kept within the treatment room for closest thermal accuracy conditions or at least placed within the room approximately 10 h before dosimetry measurements. If these options are not available, a standard linear interpolation method for calculation of temperature should be used to minimize uncertainty of temperature measurements.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4506    
    Printed108    
    Emailed0    
    PDF Downloaded233    
    Comments [Add]    
    Cited by others 1    

Recommend this journal