Radiation Dose Delivery For Total Skin Electron Therapy (Test) With Low Energy



Correspondence Address:
K Krishnamurthy


Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Clinical radiotherapy applications of low energy electrons in the treatment of total skin involvement is a complex and rarely practiced modality world over. The physics and technical aspects of execution of the techniques involve clear understanding of the use of relevant parameters. After finalizing the treatment geometry and characterizing the parameters of total skin electron treatment (TSET) beam in a linear accelerator, the treatment has to be delivered using 3 pairs of fields in the Stanford technique. There is need to find out the integrated effect of 6 fields by further dosimetric measurements to derive monitor units for single field. Measurements were performed using humanoid phantom in simulated treatment position on a rotating stool. The factor for 6 pairs' of field related from single field calibrated dose per MU is found out using a 0.6 cc Farmer chamber at two selected positions on the humanoid phantom. The overdose ratio at the junction is also quantified. Monitor units are calculated using the single field output and the 6 pairs dosimetric factor. A factor of 4.26 is derived for the 6 pairs of wide angle electron fields of the Stanford technique. The overdose ratio at the junction of 12.20 tilted upper and lower halfrbody fields is found to be 1.09. For the treatment delivery of planned dose of 1 Gy, the required mohitor units for the 6 MeV beams were 428 MU for 3 pairs of fields on alternate days. Ameasured value of 0.1063 cGy/MU on humanoid phantom'with 0.6 cc is in agreement with measured 0.1092 cGy/MU with parallel plate chamber with cubic phantom. The value of dose for 6 pairs of fields to 1 pair of fields D6p/lD1p=2.79 which agrees with the factor between 2.5 to 3.0 reported by AAPM. Our methodology in implementation of TSET will be helpful for other centers rendering this rare radiotherapy practice.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed980    
    Printed51    
    Emailed0    
    PDF Downloaded190    
    Comments [Add]    

Recommend this journal